HM-C800B 8E1 to Ethernet Converter

Model: HM-C800B

Function: Ethernet over 8E1 solution

  • Courier delivery

Our courier will deliver to the specified address

5-7 Working Days

From $40

Humanity HM-C800B 8E1 to Ethernet converter realizes Ethernet transmission over 1~8E1. 

This model complies with GFP, VCAT, LCAS and able to work with third party device followed same protocol.

Main Features

  • Realizes Ethernet transmission over E1
  • Comply with ITU-T G.7041, G.7042, G.7043, G.8040. It’s able to work with third party device followed same standard ITU protocol.
  • Support auto delete the fault E1 channels. Auto in use after E1 is normal.
  • E1 can not connect according to serial number. In case one E1 failure, the other E1 can still work.
  • For 8E1 channels, the maximum tolerable time delay difference between any two can be up to 220ms.
  • Chassis type supported
  • MBTF: 50000hours

E1:

8xE1 

Connector: DB37. Offer DB37/RJ45 or DB37/BNC adaptor

Impedance: 120ohm or 75ohm

Line code: HDB3

Comply with ITU-T G.703 standard

Jitter comply with ITU-T G.823 standard

Ethernet:

4xEthernet with VLAN

Comply with IEEE802.3, IEEE802.1Q

Connector: RJ45

Auto adapt 10/100M, full/half duplex

Support MDI/MDIX

MAC address table capability: 1024

Minimum frame length: 64bytes

Maximum frame length: 1916bytes

LED indicators:

POWER

Ethernet: LINK1-4, BT1-4

E1: ALR, L01-L08, LOS,AIS,LOOP,LOF

* ALR is general alarm

* L01-L08 is for alarm E1 channel

Choose Local/remote alarm

Choose CONSOLE/SNMP management

Set E1 loop

Set VLAN

Management:

Default with console management

SNMP option, please choose the right one when in order.

Power:

AC220V and DC-48V 

AC220V power range: AC90V~AC260V

DC-48V power range: DC-36V~DC -72V

Less than 10W

Working temperature: -5 ~ 50℃

Relative humidity: ≤95%, non-condensing